Products

Sub Categories

  • Filter

Features: MaxRange 0-5mm, pre-set to 500µm which can be changed. Resolution 0.001mm; Accuracy; ±2µm MaxRange 0.2inch, Resolution 0.00005inch. Available as metric/imperial. The reading maximum range is user adjustable.

FEATURES ● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.     SPECIFICATIONS RCD Testing Range 10mA @ 150ms 30mA @ 150ms 150mA @ 30ms Insulation Testing   Range 1MΩ / 9.9MΩ / 99MΩ Accuracy ± 1% Max. Testing 1.2kV Continuity Testing Range 0.5Ω / 2Ω / 10Ω Accuracy ± 0.05Ω / ± 0.1Ω / ± 0.2Ω Max. Current 300mA LOOP Testing Range Supply Loop / Supply Loop +1Ω Accuracy 0.45Ω ± 0.05Ω / 1.45Ω ± 0.05Ω • Dimension: 330(L)x260(W)x160(D)mm • Weight: Approx. 2570g    

Category: Test-leads

● Wire : PVC UL 1803 / 18AWG.     length : 1100±30mm    Out diameter : 3.50mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 64 / 0.12mm● Terminal :    (1) Single test plug for 2 test leads.    (2) Single test plug for easier operation.● Rating :    EN 61010-031:2002 + A1:2008    CAT III 1000V 10A / CAT IV 600V 10A

Category: Test-leads

● Wire : PVC UL 1803 / 18AWG.     length : 1100±30mm    Out diameter : 3.50mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 64 / 0.12mm● Terminal :    (1) Single test plug for 2 test leads.    (2) Single test plug for easier operation.● Rating :    EN 61010-031:2002 + A1:2008    CAT III 1000V 10A / CAT IV 600V 10A

Category: Test-leads

● Wire : PVC UL 1803 / 18AWG.     length : 1100±30mm    Out diameter : 3.50mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 64 / 0.12mm● Terminal :    (1) Single test plug for 2 test leads.    (2) Single test plug for easier operation.● Rating :    EN 61010-031:2002 + A1:2008    CAT III 1000V 10A / CAT IV 600V 10A

Category: Test-leads

● Wire : PVC UL 1803 / 18AWG.     length : 1100±30mm    Out diameter : 4.0mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 170 / 0.08mm● Terminal :    (1) Single test plug for 2 test leads.    (2) Single test plug for easier operation.● Rating :    EN 61010-031:2002 + A1:2008    CAT IV 1000V 10A

Category: Test-leads

● Wire : PVC UL 1803 / 18AWG.     length : 1100±30mm    Out diameter : 4.0mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 170 / 0.08mm● Terminal :    (1) Single test plug for 2 test leads.    (2) Single test plug for easier operation.● Rating :    EN 61010-031:2002 + A1:2008    CAT IV 1000V 10A

Category: Test-leads

● Wire : PVC UL 1803 / 18AWG.     length : 1100±30mm    Out diameter : 4.0mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 170 / 0.08mm● Terminal :    (1) Single test plug for 2 test leads.    (2) Single test plug for easier operation.● Rating :    EN 61010-031:2002 + A1:2008    CAT IV 1000V 10A