By Brands

Brands

  • Filter

Residual Chlorine Analyzer CLBM-50   Ultracompact DIN 48 size Reagenless model Auto-cleaning by polishing beads and micro-vibrating electrode Power supply: 100 - 230VAC Low power consumption of 5VA Meas. range 0 - 3 mg/L  

Reagentless Residual Chlorine Analyzer CLF-120   Measures total residual chlorine of drainage water without reagent Continuous measurement by polarographic method Meas. range 0 - 0.5/1.0, 0 - 1/2, 0 - 2/3 mg/L (ppm)  

Measures free residual chlorine of chlorinated samples from purification/food processing/semiconductor plants and pool without reagent Continuous measurement by polarographic method Meas. range CD-36D: 0 - 2 mg/L (ppm) CD-38D: 0 - 100 mg/L (ppm)

Measures free residual chlorine of clean water continuously with the reagentless polarographic method RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 1/2, 0 - 1/3, 0 - 2/3 mg/L (ppm) (2-range)

 Measures chloride demand of water and estimates chlorine injection level; best suited for feed forward control Meas. range From 0 - 5 mg/L to 10 mg/L (ppm) From 0 - 10 mg/L to 20 mg/L (ppm)

Color and turbidity can be measured simultaneously by dual wavelength with just one meter Equipped with interactive easy-to-use color touch panel Meas. range Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm)

Colorimeter/Turbidity Meter COL-110   Color and turbidity can be measured simultaneously by dual wavelength with just one meter Equipped with interactive easy-to-use colortouch panel Meas. range Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm)  

Turbidity Meter with Integrating Sphere TUI-100 Integrating sphere system employed for lab turbidity measurements Continuous measurement of turbidity in tap water, river water, industrial water, etc. Accurate results for minimized influence of color Meas. range 0 - 0.5/5 to 0 - 100/1000 Cell length: 50mm or 10mm (selectable) (mg/L, ppm, FTU, NTU)