FEATURES ● Microprocessor-controlled.● Indicates phase rotation.● Indicates phase presence.● Tests for disconnection sensitivity.● Indicates battery status.● Tests for disconnection time.● Measures voltage phase to earth.● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Very low consumption.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Led indication of Voltage on ELCB.● Phase rotation and presence does not require battery to indicate.● EN 61010-1 CAT III 550V. EN 61326-1     SPECIFICATIONS     Determination of the Phase Presence     Nominal Voltage for Phase Presence Indication (the voltage required for the neon lamps L1, L2, L3 to lit up) From 100Vac to 450Vac. Frequency Range From 10Hz to 400Hz. Determination of the Phases Rotary Field Direction   Direction (the voltage required to have the direction LEDs L1-L2-L3 or L2-L1-L3 to indicates) From 100 to 450Vac. Frequency Range From 2Hz to...

FEATURES ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.     SPECIFICATIONS       Voltage / power input     Universal IEC LEAD 240V/10A Wiring polarity check     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Elcb / rcd tester     Nominal Voltage 240Vac Frequency 50/60Hz Current Tolerance (current proportional to Line to Earth Voltage) ±10% Universal test sockets     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Fuse 10A Appliance tester     Nominal...

FEATURES ● High contrast OLED display.● Designed for viewing in the dark, for mining industry.● Microprocessor-controlled.● Indicates phase rotation● Indicates phase presence● TEST for disconnection sensitivity● Battery status indicator● Measures Voltage Phase to Earth● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Phase rotation and presence does not require battery to indicate.     SPECIFICATIONS       Nominal voltage for phase presence frequency range 100Vac to 450Vac 10Hz to 400Hz Rotary field direction phases frequency range 100 to 450Vac 2Hz to 400Hz Overload protection 550V (between all terminal) Over voltage protection Class III - 450V towards ground Current settings 999mAac /50Hz-60Hz Phase start selection 0º and 180º Phase polarity trip Indicator ˇ Operating voltage (L-E) referenced to earth 220Vac to 317Vac Timer resolution 1ms (Max....

Category: Loop Testers

FEATURES ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles    in the ground or external measuring wires.● Earth measurement uses the real earth current path   and the current generated by the electric network,   without the need for any disconnection.● The Earth Resistance displayed is exactly the earth   resistance that the earth current will need to go   through if an earth fault occurs.   (you do not need to add all the bonding points and    connection paths)● Displays voltage supply at the transformer(Line to   Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll   through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and   earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.    ...

Category: Loop Testers

FEATURES ● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and   Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at   16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results   and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.     SPECIFICATIONS       Loop impedance range L-E 0.03-2000Ω (software ctrl) Test currents in each loop 11.76A at 230V / 50Hz Voltage measurement L-N 50 to 280V AC (Sine) Load current for volt drop (L-N) 16A (Calculation) Neutral wire resistance (Not available, see 1826 NA) Line wire resistance & transformer windings (Not available, see 1826 NA) PSC current (L-N) max 6kA at 230Vac supply PSC current (L-E) max (Not available, see 1826...

Category: Loop Testers

FEATURES ● Microprocessor-controlled.● Displays and sound warning if external voltage   present.● Displays mains voltage, scroll trough menus.● Checks wiring integrity (LEDs and display).● Single button operation.● Auto-off/auto-ranging.● Combined prospective short circuit current, PSC   and LOOP tester.● Built-in carry case, test leads in separate pouch.● Loop test for L-E and L-N and PSC.● Voltage test L-N and L-E.● Enables analysis of constituent components in L-E    and L-N loops giving resistance of earth, neutral    wire, live wire and transformer winding.● Display can be customized for special orders. ● 60Hz available on request.      SPECIFICATIONS       Loop impedance range L-E, L-N 20/200/2000Ω (auto-range) Loop impedance test current 12A at 230V / 50Hz Voltage measurement L-N, L-E 80 to 250V AC/50Hz Earth wire/path return resistance 20/200/2000Ω (auto-range) Neutral wire return resistance 20/200/2000Ω (auto-range) Line wire return resistance & transformer...

FEATURES ● Microprocessor-controlled.● Measures Earth Resistance without the need for    poles in the ground or external measuring wires.● Earth measurement uses the real earth current path    and the current generated by the electric network,    without the need for any disconnection.● The Earth Resistance displayed is exactly the earth    resistance that the earth current will need to go    through if an earth fault occurs. No need to add all    the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to   Neutral), without loading the transformer.   Displays voltage between Line (Phase) and Earth      (Ground), without drawing any current.● Measures the impedance of the line itself so you can    analyze and differentiate between the multiples paths    of the wiring.● Measures the Neutral Impedance.    Single one smart push button operation; ON,...

FEATURES ● Microprocessor-controlled.● Built-in earth tester.● Built-in loop/psc tester. 0.03-2000Ω (software ctrl).● Built-in voltmeter.● Built-in wiring checker.● One push button smart control.● Display L-N and L-E voltages. 50 to 280Vac (sine).● Display line path impedance. 0.01-2000Ω (software ctrl).● Display earth path impedance. 0.01-2000Ω  (software ctrl).● Display neutral path impedance. 0.01-2000Ω  (software ctrl).● Display psc line to neutral.  6kA@230Vac> supply.● Display psc line to earth.  6kA@230Vac> supply.● Re-scroll through previous results.● Bat. ok/low battery indicator.● Auto off function.● Color-coded test leads.● Rugged case.● Ultra low power consumption.     SPECIFICATIONS       Loop / Earth / Wires 0.03-2000Ω (auto-ranging) Prospective short circuit 0~6kA at 230Vac Operating voltage 50V~275Vac (50Hz) Best performance at rated voltage 230Vac ± 20V Max.10A Accuracy of voltage ±1%(210~250V) ±3% otherwise Accuracy of loops / earth ±2% (0.05~50Ω) ...