Portable humidity meters

 

 

 

 
  • Filter

- Fast response telescoping probe. - Air flow volume. - Large LCD display. - Displays air (wind) speed in meters/second,feet/minute, kilometers/hr, knots, and miles/hr. - Displays maximum and minimum readings and holds any reading. - Manual Data Memory and read fucntion (99 records). - Auto Data memory with USB interface (30,000 records). - Dew point, Wet Bulb calculation. - Absolute pressure measurement.

Product Description- Dual display of temperature and humidity.- Select between different temperature scales (°C / °F).- Simultaneously hold both temperature and humidity readings.- Simultaneously hold both Maximum and Minimum and Average readings (MAX/MIN/AVG) with time marks.- Relative subtraction value (REL) function.- Alarm alert (SET) function.- Auto-power off.- DEW-POINT and WET-BULB temperature measurement.- Stores up to 200 readings  

- Measuring humidity, temperature, wet bulb and dew point - Quick-response capacitance sensor - Max/Min/AVG and Data Hold - Auto power off and disable function - Low battery indication - Dual LCD display

- Dataloggin, Quick-response capacitance sensor, accurate measurement for wet bulb globe temperature(WBGT), black globe temperature(TG), humidity(%RH), air temperature(TA), wet bulb(WET) and dew point(DEW). - Max/Min and data hold. - Low battery indication. - LCD display with LED backlight. - Viewing data records. - Switch the temperature unit to ℃ or ℉. - Brass black ball in 50mm diameter. - WBGT alarm setting. - Auto power off with disable function. - Data logging capacity: 12000 records, USB PC serial interface (TM-188D). - Sampling interval: Max 24 hours; Min 1 Second (TM-188D).

Displays temperature and relative humidity / wet bulb temperature / dewpoint Max./min. values Hold button to freeze readings Display light Auto Off function TopSafe, the indestructible protection case (optional) Patented humidity sensor 2 year guaranteed long-term stability TopSafe, instrument protection against dirt and knocks (optional) Go for TST0191 if you do not need a cable  

Humidity and temperature measuring instrument incl. protective cap, batteries and calibration protocol TST0102 measures relative air moisture and temperature simultaneously. Dew point calculation and wet bulb as well as Hold function and max./min. display are possible with this instrument. Long-term stable Testo humidity sensor +/-2.5 %RH accuracy Incl. calibration protocol Dewpoint calculation and wet bulb included Hold function and max./min. values Protective cap for safe storage Belt case, wrist strap and calibration protocol included Backlit display Air moisture and air temperature Storage temperature -40 to +70 °C Operating temperature -10 to +50 °C Battery type 2 batteries Type AAA Battery life 200 h Weight 90 g Dimensions 119 x 46 x 25 mm Probe type NTC Meas. range -10 to +50 °C Accuracy ±0.5 °C Resolution 0.1 °C Probe type humid. sensor, cap. Meas. Range 0 to 100 %RH Accuracy ±2.5 %RH (5 to 95 %RH) Resolution 0.1 %RH

Laboratory Quality Control Air-Conditioning Process Engineering Range: Humidity 10% to 95% R.H. Temperature -20 ℃ to +60 ℃ ; -4 o F to +140 ℉ Resolution 0.1% R.H. 0.1 ℃ , 0.1 ℉ Accuracy (after calibration) Humidity +/ - 3% R.H. (at 25 ℃ , 30...95% R.H.) Temperature +/ - 0.8 ℃ , +/ - 1.5 ℉ Response time Humidity 45% R.H. --> 95% R.H. < = 3min 95% R.H. --> 45% R.H. < =5min Temperature 1 ℃ /2 sec Accessories Carrying case, Instruction manual, Battery. Auxiliary outputs Humidity 10mV DC/1% R.H. Temperature 10mV DC/1 o C, 10mV DC/1 o F Operating / Storage Condition 0 ℃ to 50 ℃< 80% R.H. -10 ℃ to 60 ℃< 70% R.H. Power Source 10mV DC/1 ℃ , 10mV DC/1 ℉ Size 270mm(L)x68mm(W)x25mm(H) Weight 200g Accessories Instruction Manual, Battery and Carrying Case    

* Triple LCD Display for RH% Humidity, T1 for Air Temperature and T2 Type K Thermometer (-200 ℃ ~ 1333 ℃ ). * Dew Point Reading. * Max / Min / Data Hold. * Real Time Stamp. * Periodically Print out from Pre-Set time Interval. Measuring Range T1 : Temperature : - 20 ℃ ~ 60 ℃ (- 4 ℉ ~ 140 ℉ ) Humidity : 10%RH ~ 95%RH T2 : Type K : - 200 ~ 1333 ℃ (- 58 ~ 2431 ℉ ) Resolution 0.1 ℃ /0.1 ℉ /0.1%RH Accuracy T1 : Temperature : +/- 0.8 ℃ , +/- 1.5 ℉ Humidity : +/- 3%RH (at 25 o C, 30….95%RH) T2 : Type K : - 50 ℃ ~ 500 ℃ , +/- (0.1%rdg + 0.8 ℃ ) 500 ℃ ~ 1333 ℃ , +/- (0.2%rdg + 1.8 ℃ ) Input Protection 60V DC or 24 Vrms AC maximum input voltage on any Combination of input Connector. Sampling Rate 1 time/sec Operating Conditions 0 ℃ ~ 40 ℃ (32 o F ~ 104 ℉ ) 10 ~ 80% R.H. Power Source 6 pcs size AAA Alkaline Battery or 9V DC adaptor/500mA minimum. Battery Life Approx. 30 hours. ( interval printing = 60 minute, not including beeper). 70 hours ( except printing & beeper). Size 193(L) x 74(W) x 37(H)mm Weight Approx. 385g Accessories 1. Carrying case, Instruction manual,...