Datalogger/Recorders
* Acceleration : 200 m/s2. Velocity : 200 mm/s. Displacement : 2.0 mm. * Max hold, peak value, data hold. * Memory ( Max., Min. ) * LCD display with bar graph. * 500 point data logger. * Zero adjustment, RS232 computer interface. * Optional data transmission software, SW-DL2005. * Accelerator and hard carrying case are included.
* Acceleration : 200 m/s2. Velocity : 200 mm/s. Displacement: 1.999 mm * Max hold, peak value, data hold. * Memory ( Max., Min. ). * RS232/USB computer interface, Patented. * Vibration sensor is the standard accessory. * Patent: Taiwan, China, Japan, Germany, USA pending.
Complete vibration monitor -Velocity Measurement -Acceleration Measurement -Displacement Measurement -Direct Graphical Analysis
Recorder with real time data logger, save the measuring data along the time information ( year, month, date, hour, minute, second ) into the SD memory card and can be downloaded to the Excel, extra software is no need. * Frequency range 10 Hz - 1 KHz, sensitivity relative meet ISO 2954. * Meter supply with vibration sensor and magnetic base, full set. * Acceleration : 200 m/s^2. Velocity : 200 mm/s. * Built-in the 4 to 20 mA output signal, it can cooperate with the 4 to 20 mA controller to be used as the vibration controller. * Metric & Imperial display unit. * Large LCD display, easy readout. * Power supply from DC 9V adapter in, power adapter is included. Also it needs DC 1.5V ( UM-4/AAA ) battery x 6 PCs for clock power supply. * RS232/USB computer interface. * Size : 132 x 80 x 32 mm
• Range : - Light : 0 to 100,000 LUX - thermometer : -50.0 to 1300.0 ℃ • Accuracy : - Light : ± (4 %+2 dgt) - thermometer : ± ( 0.4 % + 0.5 ℃ ) FEATURES : • 3 ranges, 2,000/20,000/100,000 LUX. • LUX & Foot Candle unit selection with default. • Auto range for light measurement. • Spectrum of photo sensor meets C.I.E.. • Light measurement with zero adjustment by push button. • Separate probe, easy for operation of different measurement environment. • Type K, Type J thermocouple thermometer. • SD card capacity : 1 GB to 16 GB. • LCD with green light backlight, easy reading. • Can default auto power off or manual power off. • Data hold, record max. and min. reading. • Microcomputer circuit, high accuracy. • RS232/USB PC COMPUTER interface. • Weight : 489 g/1.08 LB. • Dimension : 177 x 68 x 45 mm Accessories Included • Instruction manual...............................1 PC • Light sensor with protective cover.... 1 PC • Soft carrying case ( CA-05 )................1 PC
Features: •Analysis for 3 phase multi-power system, 1P/2W, 1P/3W,3P/3W, 3P/4W •3 current probes ( CP-1201 ) are included, if change the current probes, the calibration procedures are not necessary •Current probe input signal/ranges with selection:Input signal (ACV):200 mV/300 mV/500 mV/1 V/2 V/3 VRanges (ACA) : 20 A/200 A/2000 A/30 A/300 A/ 3000 A. •Meter can cooperate the universal current probes •Measurement: V (phase-to-phase), V (phase-to-ground) A (phase-to-ground) KW / KVA / KVAR / PF (phase) KW / KVA / KVAR / PF (system) KWH / KVAH / KVARH / PFH (system) Phase angle •Harmonics display (1-50th order) •Simultaneous display of Harmonics and Wave form •Display of Waveform with Peak Values •Analysis of Total Harmonic Distortion ( THD ) •Graphic Phase diagram with 3-Phase system parameters •3 phase Voltage or Current Unbalanced Ratio ( VUR, AUR ) and Unbalanced Factor •Calculated Unbalanced Current through Neutral Line ( An ) Standard Accessories: * Instruction manual............... 1 PC * Test Leads (TL88-4AT).......... 1 Set (4 PCs) * Alligator clips (TL88-4AC) 1 Set (4 PCs) * Clamp Probe ( CP-1201 )....... 3 PCs * AC to DC 9V adapter..............1...
Features: •Analysis for 3 phase multi-power system, 1P/2W,1P/3W, 3P/3W, 3P/4W •Voltage & Current are the True RMS value. •True Power ( KW、MW、GW ) measurement. •Apparent Power ( KVA、MVA、GVA ) measurement. •Reactive Power ( KVAR MVAR、GVAR) measurement. •Watt-Hour ( WH、SH、QH、PFH ). •Power Factor( PF )、Phase Angle( Φ ). •Voltage measurement range : 10 to 600 ACV •Current measurement range: 0.2A to 1200 ACA. •Programmable CT ratio (1 to 600) and PT ratio (1 to 1000). •ACV input impedance is 10 Mega ohms. •Safety Standard : IEC 1010, CAT III 600V •Built-in clock and Calendar, real time data record with SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/data/hour/mimute/second ) to the Excel directly, then user can make the further data analysis by themselves. •Measurement: * ACV * ACA * AC WATT ( True Power )AC WATT( Apparent Power )AC WATT( Reactive Power ) * Power factor * Phase angle * Frequency Standard Accessories: * Instruction manual.......................1 PC * Test Leads...
*DESKTOP & WALL MOUNT TEMP./ HUMID. DATALOGGER *DATALOGGING into SD CARD, No software, No cables. SD card 1 GB to 16 GB Open with Microsoft Excel! Easy!RS232/USB PC COMPUTER interface