By Brands

Brands

  • Filter

Save money and time by taking multiple measurements simultaneously Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules Capture readings at different intervals, with user-set recording intervals from one second to one hour Choose the module(s) that work best for your applications Identify up to 10 placed modules with meter or PC and choose only the ones you need View up to 10 live readings at once on a PC to get a complete understanding of the situation Easily see backlit displays in dark or dimly lit work environments Choose auto or manual ranging Use the optional TPak magnetic hanger for even more hands-free working Integrated holster protects the meters, while probe holders keep accessories organized Increase safety by taking readings in a separate location than the point of measurement Fluke CNX meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards: AC current clamp 600 V CAT III; AC Voltage Module and iFlex Clamp Meters 600 V CAT IV / 1000 CAT III

Save money and time by taking multiple measurements simultaneously Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules Capture readings at different intervals, with user-set recording intervals from one second to one hour Choose the module(s) that work best for your applications Identify up to 10 placed modules with meter or PC and choose only the ones you need View up to 10 live readings at once on a PC to get a complete understanding of the situation Easily see backlit displays in dark or dimly lit work environments Choose auto or manual ranging Use the optional TPak magnetic hanger for even more hands-free working Integrated holster protects the meters, while probe holders keep accessories organized Increase safety by taking readings in a separate location than the point of measurement Fluke CNX meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards: AC current clamp 600 V CAT III; AC Voltage Module and iFlex Clamp Meters 600 V CAT IV / 1000 CAT III

Your tools - connected. Take readings quicker. Solve problems faster. Fluke CNX 3000 wireless test tools work together to help you troubleshoot faster. With the CNX team, measurements are: Remote Simultaneous Recordable The Fluke CNX Wireless System is a troubleshooting system with a digital multimeter as the core device. The DMM receives and displays up to three voltage, amperage and/or temperature readings from multiple wireless modules placed in a variety of locations up to 20 meters away. The modules include AC Voltage, AC Current Clamp, iFlex AC Current Clamp, and K-Type Temperature units. There is also a PC Adapter for downloading and analyzing data from the system. For more complex troubleshooting scenarios, set a computer with the adapter within 20 meters of modules and view live readings from up to 10 modules simultaneously.

MadgeTechs Vaccine Temperature Monitoring System (VTMS) is ideal for the continuous measurement and data logging of temperature sensitive vaccines or pharmaceuticals in refrigerators, freezers, and coolers. The system includes a NIST traceable RFTCTemp2000A data logger with thermocouple, Glycol bottle and a power supply. Additionally, the RFTCTemp2000A data logger in the VTMS system has a convenient LCD to ensure temperature parameters are met, in real time. The current reading, minimum, maximum and average statistics can all be obtained through the display. In the real-time chart recording mode the VTMS can alert the user, or other personnel, via e-mail or text message if the refrigerator has failed, or if the temperature is outside of the nominal range. This allows users to take immediate actions to ensure vaccines and pharmaceuticals in storage are not destroyed. To prevent false alarms, the RFTCTemp2000A is connected to a Glycol bottle which provides temperature buffered readings.

The RFCurrent2000A is a wireless data logger with display, designed to measure and record DC current signals. The data logger can connect directly to low-level DC current sources which makes it ideal for (PV) Photovoltaic research to monitor current sourced from solar cells over time, battery usage studies, energy monitoring studies and other DC current monitoring applications. The RFCurrent2000A can also be interfaced with a wide range of current output sensors such as flow meters, pH transmitters and more. Through the software, the device can be programmed with engineering units, which convert the current readings into a different unit of measure such as flow rate. The engineering unit is available for display on the LCD screen as well as in the software. The RFCurrent2000A is available in 20mA, 160mA or a 3A measurement range.   The RFCurrent2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics. The statistics can be reset through the keypad of the device, allowing customers to keep track of statistics over certain time periods. This feature does not erase the data recorded, but only resets the...

MadgeTech’s RFOT is the most advanced wireless temperature data logger in the meat industry today. The RFOT’s rugged design, equipped with a flexible piercing probe allows it to be used in the harshest environments. It is perfectly suited for smoke houses, ovens and other cooking processes up to 212°F (100°C) as well as refrigerators and freezers down to -4°F (-20°C). It is completely splash proof and can withstand wash down cycles. This state-of-the-art device records and transmits internal product temperature readings back to a central computer for instant real-time monitoring. The RFOT never needs to be connected to a computer as it has been designed for two way wireless communication. Full communication can be performed directly from a central PC. In addition to wirelessly transmitting data, the RFOT also stores each reading to internal memory for backup. This backup data may be retrieved wirelessly at a later time. MadgeTech’s easy to use software features user programmable critical control points, called “cooling flags” to assist in compliance with USDA Appendix B. The “cooling flags” are automatically annotated on the graph and tabular data views. The...

The RFPulse2000A is a wireless data logger that records pulse output signals from various sensors such as flow meters and anemometers. When started, the data logger samples at 100Hz and at the user specified reading rate, recording the total number of pulses from the sample to memory. The RFPulse2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics. Through the software the device can be programmed to convert the pulse output into a different unit of measure such as gallons per minute or miles per hour. This information can be viewed on the LCD screen of the data logger as well as in the software. The RFPulse2000A is unique in that it not only calculates pulse count, but it also calculates pulse rate. Engineering units can be programmed into the device as a rate, which allows the device to calculate the measurement unit in rates per second, minute, hour or per day. This provides more useful statistics to the user when data logging over long periods of time. The RFPulse2000A can be used as a standalone data logger, or used with the RFC1000 wireless transceiver, to wirelessly transmit data back to a central PC....

The RFRHTemp2000A is two-way Wireless temperature and humidity data logger with LCD. Transmits up to 2000' maximum (outdoors unobstructed). Built-in memory also stores data internally. This device is calibrated traceable to N.I.S.T. and is available with a Calibration Certificate. The RFRHTemp2000A is ideal for both industrial or laboratory applications including supply chain storage facilities, incubator monitoring and HVAC studies. Designed with external humidity and RTD based temperature sensors, the device provides a fast response time for both parameters. For customer convenience, functions include starting, stopping and downloading from the device wirelessly using the RFC1000 wireless transceiver. This allows customers to quickly access data and spend less time maintaining the device. Data can be provided in real time back to a central PC, or the device may be downloaded at periodic intervals. The digital display provides the current reading for both the humidity and temperature channels with minimum, maximum and average statistics accessible for a quick snapshot of the logged data. The RFRHTemp2000A features user programmable alarm settings for both temperature and...