By Brands

Brands

  • Filter
Category: Megger

Evaluate the capability of link connections and locate faults up to 500 meters Detect Wiremap failure (Pass/Fail) RJ45 and BNC connectors 10BASE-T and 100BASE-TX Ethernet, half- or full- duplex support 1000BASE-T, Auto measurement of signal performance, wiremap and length 1 kHz analogue tone signal output suitable for all probe sets

Category: Megger

est Voltages of 100/250/500/1000 VDC Insulation resistance measurements up to 20 GΩ 0 to 5000Ω Continuity Range Guard terminal to eliminate surface leakage current Hand-Cranked Large easy-to-read scale

Category: Megger

210400: 5 kV, 100 GΩ 210415: 15 kV, 300 GΩ Zero-start, high-voltage interlock Shielded, high-voltage output cable permanently connected to the instrument Redundant grounding connections Easy-to-follow, color-coded meter scales Continuously variable test voltage Rugged field construction Circuit-breaker protection

Category: Megger

210400: 5 kV, 100 GΩ 210415: 15 kV, 300 GΩ Zero-start, high-voltage interlock Shielded, high-voltage output cable permanently connected to the instrument Redundant grounding connections Easy-to-follow, color-coded meter scales Continuously variable test voltage Rugged field construction Circuit-breaker protection

Category: Megger

Test Voltages of 100/250/500/1000 VDC Insulation resistance measurements up to 1999 MΩ 0 to 600 VAC Measuring Range Guard terminal to eliminate surface leakage current Battery Operated Autoranging Large easy-to-read 3Ω LCD display

Category: Megger

No scale multipliers Multiple test voltages for spot and step voltage testing Guard terminal to eliminate surface leakage current Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm Available in alternate configurations: 212359 - Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply 212459 - Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests 212559 - Dual operation 120 V 50/60 Hz mains (line) supply and rechargeable battery. Six NiMh 1800 mAh cells

Category: Megger

No scale multipliers Multiple test voltages for spot and step voltage testing Guard terminal to eliminate surface leakage current Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply Available in alternate configurations: 212159 - Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm 212459 - Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests 212559 - Dual operation 120 V 50/60 Hz mains (line) supply and rechargeable battery. Six NiMh 1800 mAh cells

Category: Megger

No scale multipliers Multiple test voltages for spot and step voltage testing Guard terminal to eliminate surface leakage current Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests Available in alternate configurations: 212159 - Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm 212359 - Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply 212559 - Dual operation 120 V 50/60 Hz mains (line) supply and rechargeable battery. Six NiMh 1800 mAh cells