  • Filter

Laboratory Quality Control Air-Conditioning Process Engineering Range: Humidity 10% to 95% R.H. Temperature -20 ℃ to +60 ℃ ; -4 o F to +140 ℉ Resolution 0.1% R.H. 0.1 ℃ , 0.1 ℉ Accuracy (after calibration) Humidity +/ - 3% R.H. (at 25 ℃ , 30...95% R.H.) Temperature +/ - 0.8 ℃ , +/ - 1.5 ℉ Response time Humidity 45% R.H. --> 95% R.H. < = 3min 95% R.H. --> 45% R.H. < =5min Temperature 1 ℃ /2 sec Accessories Carrying case, Instruction manual, Battery. Auxiliary outputs Humidity 10mV DC/1% R.H. Temperature 10mV DC/1 o C, 10mV DC/1 o F Operating / Storage Condition 0 ℃ to 50 ℃< 80% R.H. -10 ℃ to 60 ℃< 70% R.H. Power Source 10mV DC/1 ℃ , 10mV DC/1 ℉ Size 270mm(L)x68mm(W)x25mm(H) Weight 200g Accessories Instruction Manual, Battery and Carrying Case    

POCKET HUMIDITY METER, economical type * Measurement : Humidity, Temp., Dew point * Pocket and compact housing case. * Fast response time. * Humidity : 10 to 95 %RH , Temp. : 0 to 50 oC. * Resolution : 0.1 %RH, 0.1 degree. * DC 9V battery (006P). * Separate probe. * Size : 135 x 60 x 33 mm.

* Triple LCD Display for RH% Humidity, T1 for Air Temperature and T2 Type K Thermometer (-200 ℃ ~ 1333 ℃ ). * Dew Point Reading. * Max / Min / Data Hold. * Real Time Stamp. * Periodically Print out from Pre-Set time Interval. Measuring Range T1 : Temperature : - 20 ℃ ~ 60 ℃ (- 4 ℉ ~ 140 ℉ ) Humidity : 10%RH ~ 95%RH T2 : Type K : - 200 ~ 1333 ℃ (- 58 ~ 2431 ℉ ) Resolution 0.1 ℃ /0.1 ℉ /0.1%RH Accuracy T1 : Temperature : +/- 0.8 ℃ , +/- 1.5 ℉ Humidity : +/- 3%RH (at 25 o C, 30….95%RH) T2 : Type K : - 50 ℃ ~ 500 ℃ , +/- (0.1%rdg + 0.8 ℃ ) 500 ℃ ~ 1333 ℃ , +/- (0.2%rdg + 1.8 ℃ ) Input Protection 60V DC or 24 Vrms AC maximum input voltage on any Combination of input Connector. Sampling Rate 1 time/sec Operating Conditions 0 ℃ ~ 40 ℃ (32 o F ~ 104 ℉ ) 10 ~ 80% R.H. Power Source 6 pcs size AAA Alkaline Battery or 9V DC adaptor/500mA minimum. Battery Life Approx. 30 hours. ( interval printing = 60 minute, not including beeper). 70 hours ( except printing & beeper). Size 193(L) x 74(W) x 37(H)mm Weight Approx. 385g Accessories 1. Carrying case, Instruction manual,...

Dew point and wet bulb temperature measurement Fast response Auto Power off Dual display for temperature and humidity MAX/MIN function Resolution 0.1°C, 0.1°F, 0.1%RH

humidity/temperature instrument, incl. plug-in humidity probe head, battery and calibration document Displays temperature and relative humidity / wet bulb temperature / dewpoint Max./min. values Hold button to freeze readings Display light

    Storage temperature -30 to +70 °C Operating temperature -20 to +50 °C Battery type Alkali manganese, mignon, Type AA Battery life 200 h Weight 428 g Dimensions 220 x 74 x 46 mm Material/Housing ABS/TPE/Metal Probe - Typ T (Cu-CuNi) Meas. range -200 to +400 °C Accuracy ±0.3 °C (-60 to +60 °C) ±0.5% of mv (remaining range) Resolution 0.1 °C Probe - NTC Meas. range -40 to +150 °C Accuracy ±0.2 °C (-25 to +74.9 °C) ±0.4 °C (-40 to -25.1 °C) ±0.4 °C (+75 to +99.9 °C) ±0.5% of mv (remaining range) Resolution 0.1 °C Probe type Type K Meas. Range -200 to +1370 °C Accuracy ±0.3 °C (-60 to +60 °C) ±(0.2 °C + 0.3% of mv) (remaining range) Resolution 0.1 °C Probe type Absolute pressure probe Meas. Range 0 to 2000 hPa Resolution 0.1 hPa Probe type humid. sensor, cap. Meas. Range 0 to +100 %RH Resolution 0.1 %RH

- Fast response telescoping probe. - Air flow volume. - Large LCD display. - Displays air (wind) speed in meters/second,feet/minute, kilometers/hr, knots, and miles/hr. - Displays maximum and minimum readings and holds any reading. - Manual Data Memory and read fucntion (99 records). - Auto Data memory with USB interface (30,000 records). - Dew point, Wet Bulb calculation. - Absolute pressure measurement.